Sign In | Join Free | My entremaqueros.com
China Taizhou Zecen Biotech Co.,Ltd. logo
Taizhou Zecen Biotech Co.,Ltd.
Innovation For Health,Quality For Life
Active Member

3 Years

Home > Chemiluminescence Calibrator Kit >

AFP/F-HCGβ/FE3/PAPP-A Chemiluminescence Calibrator Kit For Automatic Immunoassay Analyzer

Taizhou Zecen Biotech Co.,Ltd.
Contact Now

AFP/F-HCGβ/FE3/PAPP-A Chemiluminescence Calibrator Kit For Automatic Immunoassay Analyzer

Brand Name : ZECEN

Model Number : Calibrator

Certification : CE

Place of Origin : Jiangsu, China

MOQ : 50 boxes

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 100000 boxes per month

Delivery Time : 10 working days

Name : AFP/F-hCGβ/FE3/PAPP-A Calibrator

Analyzer : CIA series & POCT in ZECEN

Storage : 2-8℃

Period of validity : 18 months

Contact Now

AFP/F-hCGβ/FE3/PAPP-A Calibrator for Automatic Immunoassay Analyzer

A calibrator is a reference material, a material or substance whose value for one or more properties is only uniform and well established enough to calibrate a measurement system, evaluate a measurement procedure, or assign a value to a material. There are high and low 2 different concentrations.

Product composition Two points: AFP/F-hCGβ/FE3/PAPP-A
Six points: Not free
Testing method 1. Treat the calibrator as the sample to be tested, and place it in the sample loading area of the instrument after mixing. Note that when mixing Avoid air bubbles.
2. During the detection, the system detects the luminescence value (RLU value) of each calibration point, and calculates the luminescence value according to the nominal concentration and luminescence value.
The calibration curve is automatically fitted by the instrument. In order to ensure the reliability of the calibration curve, the determination of the calibrator should be
Make a double.
3. The generated calibration curve can be used for 28 days, but it should be re-calibrated after the following conditions:
① Change of batch number of supporting testing reagents;
Change of batch number of luminescent substrate
②The measured value of the quality control product is not within the scope of quality control or the test results are inconsistent with the clinical situation;
③System for major repairs or maintenance.
1. For reasons such as methodology or antibody specificity, the same sample was tested using reagents from different manufacturers.
Testing with different reagents may give different test results, therefore, the results obtained by testing with different reagents should not be directly
They are compared with each other in order to avoid false medical interpretations.
2. The quality control product can be used as a reference for the reliability of the current experimental results, and its measured value should be within the
within the range allowed by the quality control sheet. Test results should be based on reference value ranges and other clinical factors and results
Comprehensive judgment, when the test result is close to the upper limit or lower limit of the reference value range, it can be considered
samples for confirmation testing.
Storage and expiration date Stored at 2-8°C, the product is valid for 12 months. Reagents should be used within 1 month after opening, and stored at 2-8°C away from direct sunlight.

Product Tags:

PAPP-A Chemiluminescence Calibrator Kit

      

FE3 Chemiluminescence Calibrator Kit

      

AFP PAPP-A

      
 AFP/F-HCGβ/FE3/PAPP-A Chemiluminescence Calibrator Kit For Automatic Immunoassay Analyzer Manufactures

AFP/F-HCGβ/FE3/PAPP-A Chemiluminescence Calibrator Kit For Automatic Immunoassay Analyzer Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Taizhou Zecen Biotech Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)